Use 300-615 Exam Dumps (2021 PDF Dumps) To Have Reliable 300-615 Test Engine
300-615 PDF Recently Updated Questions Dumps to Improve Exam Score
NEW QUESTION 41
A Cisco UCSB-Series Blade Server is configured to boot a VMwareESXi host from an EMC VNX storage array by using a Fibre Channel SAN. The boot order is confirmed to be configured as expected but the server fails to boot from the SAN. Which action reserves the problem?
- A. Set the same WWNN pools for vHBA adaptor
- B. Set the boot LUN to the lowest LUN ID in the storage array
- C. Set the same WWPN pools for vHBA adapters
- D. Set the boot LUN to the highest LUN ID in the storage array
Answer: B
NEW QUESTION 42
Refer to the exhibit.
Cisco UCS Manager is being upgraded using the Auto Install feature, but the FSM fails. Which action resolves the issue?
- A. Acknowledge the primary fabric interconnect.
- B. Remove the service pack from the subordinate fabric interconnect.
- C. Clear the startup version of the default infrastructure pack.
- D. Upgrade the firmware of the infrastructure firmware by using the force option.
Answer: C
NEW QUESTION 43 
Refer to the exhibit. The initiator that has FC ID 0x970102 fails to communicate with the target that has FC ID 0x970200. What action resolves the issue?
- A. Reset the port for FC ID 0x970102 and FC ID 0x970200 to log in to the fabric.
- B. Reset the port for FC ID 0x970209 and FC ID 0x9700c2 to log in to the fabric.
- C. Reactivate the zoneset.
- D. Reconfigure the initiator and the target to be in the same zones.
Answer: C
Explanation:
Section: Storage Network
NEW QUESTION 44
Refer to the exhibit.
Partial configuration from N9K-1 and N9K-2 is included. The client has two WANs connected.
* WAN-1 is for normal business-day activities.
* WAN-2 is for server backups during nonworking hours of 1:00 a.m. to 5:00 a.m. daily.
The client says that at the scheduled time for backup, the data center server failed to use the WAN-2 link to back up the servers to the cloud backup system. What is the solution to this problem?
- A. The Cron entry must be configured without double quotes.
- B. The applet called "Backup" must include an action to remove the current static route.
- C. The event timer must be written in epoch time format.
- D. The Cisco Nexus switch must be configured with one applet because a configuration with two applets will fail.
Answer: B
NEW QUESTION 45
Refer to the exhibit.
A new Cisco Nexus 5548 Switch connects to a network. SAN switching is configured on the switch. The switch fc2/10 NP uplink is shown in the exhibit. Which action ensures that fc2/10 is in an up state?
- A. Configure the admin port type E on the upstream switch that connects the port.
- B. Replace the SFP port module in fc2/10.
- C. Configure the BB_credit buffers on the upstream switch that connects the port.
- D. Enable NPIV on the upstream switch that connects the port.
Answer: D
NEW QUESTION 46
A mission-critical server is connected to site A.
Connectivity to this server is lost from site B because the MAC route is missing in the OTV VDC of the Nexus 7000 in site B due to MAC aging. Which action allows the flooding of the unknown unicast MAC on the Nexus 7000 in the OTV VDC?
- A. Use route-map to advertise this MAC statically and redistribute with ISIS.
- B. Use the otv flood mac <> command to selectively flood traffic for a given MAC.
- C. Use the otv isis bfd <> command to configure BFD protocol.
- D. Unknown unicast flooding is not allowed.
Answer: B
NEW QUESTION 47
Refer to the exhibit.
A new Cisco Nexus 5548 Switch connects to a network. SAN switching is configured on the switch. The switch fc2/10 NP uplink is shown in the exhibit. Which action ensures that fc2/10 is in an up state?
- A. Configure the admin port type E on the upstream switch that connects the port.
- B. Replace the SFP port module in fc2/10.
- C. Configure the BB_credit buffers on the upstream switch that connects the port.
- D. Enable NPIV on the upstream switch that connects the port.
Answer: D
NEW QUESTION 48
Refer to the exhibit.
A switch is being downgraded to an earlier release because of a problem with the current release. After the switch is downgraded, it can no longer forward traffic. Which action resolves the issue?
- A. Roll back to the original image.
- B. Reload the switch.
- C. Shut and no shut the interfaces to the FEX.
- D. Enable ISSD after the downgrade is complete.
Answer: A
NEW QUESTION 49
An engineer enables the packet postcards feature on a Cisco Nexus 9000 Series Switch but receives this error message:
"Error: Cannot configure postcard when inband-telemetry is configured." Which action resolves the issue?
- A. Disable the hardware-telemetry feature.
- B. Disable the telemetry feature.
- C. Disable the inband-telemetry feature.
- D. Disable the software-telemetry feature.
Answer: A
Explanation:
Section: Management and Operations
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/92x/programmability/ guide/b-cisco-nexus-9000-series-nx-os-programmability-guide-92x/b-cisco-nexus-9000-series-nx-os- programmability-guide-92x_chapter_0100001.html
NEW QUESTION 50 
Refer to the exhibit. The connection between a Cisco Nexus 5548UP switch and a Cisco MDS switch fails to initialize. What is the cause of the issue?
- A. The interface is in an incorrect mode.
- B. Trunk mode must be activated.
- C. VSAN 1 is suspended.
- D. The SFP is unsupported.
Answer: B
Explanation:
Section: Storage Network
NEW QUESTION 51 
Refer to the exhibit. An attempt to bind the Ethernet interface to vFC fails. Which action resolves the issue?
- A. Configure the FCoE VLAN that corresponds to the vFC VSAN as a private VLAN.
- B. Configure the interface as a trunk port.
- C. Add the FCoE VLAN to the allowed VLAN list.
- D. Configure the interface to use the native VLAN of the trunk port.
Answer: B
Explanation:
Section: Storage Network
NEW QUESTION 52
A Cisco UCS B-Series Blade Server is configured to boot a VMware ESXi host from an EMC VNX storage array by using a Fibre Channel SAN. The boot order is confirmed to be configured as expected, but the server fails to boot from the SAN. Which action resolves the problem?
- A. Set the boot LUN to the lowest LUN ID in the storage array.
- B. Set the same WWNN pools for vHBA adapters.
- C. Set the boot LUN to the highest LUN ID in the storage array.
- D. Set the same WWPN pools for vHBA adapters.
Answer: B
Explanation:
Section: Storage Network
NEW QUESTION 53
An engineer troubleshoots a fabric discovery failure. Which two requirements about switch connectivity must be verified to solve the problem? (Choose two.)
- A. A Cisco APIC must be attached to a spine node only.
- B. Spine nodes must connect to other spine nodes.
- C. A Cisco APIC must be dual-attached to two separate spine nodes.
- D. A Cisco APIC must be attached to leaf nodes.
- E. Leaf nodes must connect to spine nodes only.
Answer: D,E
Explanation:
Section: Network
NEW QUESTION 54
During a boot process of a Cisco UCS C-Series Rack Server, an engineer receives a "No Signal" message from the vKVM and physical connection. Which set of steps resolves the issue?
- A. 1- Power off the server and disconnect the power cord
2- Confirm that all cards are available
3- Connect the power cord and power on the server - B. 1- Disconnect the power cord
2- Confirm that all cards are properly seated
3- Connect the power cord - C. 1- Disconnect the power cord
2- Confirm that all cards are property seated
3- Connect the power cord and power on the server - D. 1- Power off the server and disconnect the power cord
2- Confirm that all cards are property seated
3- Connect the power cord and power on the server
Answer: D
Explanation:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/ts/guide/b_C-Series_Troubleshooting_Guide.pdf
NEW QUESTION 55
After upgrading a client's fabric interconnect to the latest version, an engineer discovers that the appliance has lost its entire configuration. Which two locations should an engineer check to confirm that the appliance had backed up the configuration prior to the upgrade in order to retrieve the lost configuration? (Choose two.)
- A. Service profiles page, InternalBackup stage
- B. Equipment FSM page, PollInternalBackup stage
- C. Admin page, InternalBackup stage.
- D. Admin page, PollInternalBackup stage
- E. Equipment FSM page, InternalBackup stage
Answer: D,E
Explanation:
Section: Management and Operations
NEW QUESTION 56
An engineer attempts to register Cisco UCS Manager to Cisco UCS Central, but the registration fails. The engineer can ping Cisco UCS Central from UCS Manager. Which two actions must the engineer attempt to resolve the problem? (Choose two.)
- A. Allow port 443 between Cisco UCS Manager and Cisco UCS Central.
- B. Place Cisco UCS Manager on the same subnet as Cisco UCS Central.
- C. Apply the UCS Central license to UCS Central.
- D. Allow port 9443 between Cisco UCS Manager and Cisco UCS Central.
- E. Synchronize the date and time to NTP for Cisco UCS Central and the Cisco UCS domains.
Answer: A,E
Explanation:
Section: Compute Platforms
NEW QUESTION 57
Refer to an exhibit.
An engineer is troubleshooting an upgrade failure on a switch. Which action resolves the issue?
- A. Reload the same system image.
- B. Use the same system image as the kickstart image.
- C. Load a new system image.
- D. Save the system image in NVRAM.
Answer: C
NEW QUESTION 58 
Refer to the exhibit. Partial configuration from N9K-1 and N9K-2 is included. The client has two WANs connected.
* WAN-1 is for normal business-day activities.
* WAN-2 is for server backups during nonworking hours of 1:00 a.m. to 5:00 a.m. daily.
The client says that at the scheduled time for backup, the data center server failed to use the WAN-2 link to back up the servers to the cloud backup system. What is the solution to this problem?
- A. The Cron entry must be configured without double quotes.
- B. The applet called "Backup" must include an action to remove the current static route.
- C. The event timer must be written in epoch time format.
- D. The Cisco Nexus switch must be configured with one applet because a configuration with two applets will fail.
Answer: B
Explanation:
Section: Automation
Explanation
NEW QUESTION 59
Refer to the exhibit.
A switch is being downgraded to an earlier release because of a problem with the current release. After the switch is downgraded, it can no longer forward traffic. Which action resolves the issue?
- A. Roll back to the original image.
- B. Reload the switch.
- C. Shut and no shut the interfaces to the FEX.
- D. Enable ISSD after the downgrade is complete.
Answer: A
NEW QUESTION 60
A Fibre Channel interface on a Cisco Nexus 5000 Series Switch receives bit errors, and the switch disables the interface. A temporary workaround must be implemented before the root cause is identified. Which action does an engineer take to prevent this issue from reoccurring?
- A. Run the switchport ignore bit-errors command on the interface.
- B. Verify that the SFPs are supported.
- C. Run the shutdown and then no shutdown command on the interface.
- D. Change the SFP to operate at 4 Gbps instead of 2 Gbps.
Answer: A
Explanation:
Section: Storage Network
Explanation
NEW QUESTION 61
Refer to the exhibit. A network engineer deploys scripts to the guest shell of a Cisco Nexus switch. The scripts fail to operate properly due to the limited CPU and file system resources that are assigned by default to the guest shell. The engineer allocated more memory and disk space to the guest shell, but the application continues to fail. Which action resolves the issue?
- A. Reboot the guest shell
- B. Disable and enable bash shell
- C. Redeploy the bash shell
- D. Upgrade the guest shell
Answer: A
Explanation:
Reference:
https://www.ciscolive.com/c/dam/r/ciscolive/us/docs/2018/pdf/BRKDCN-2015.pdf
NEW QUESTION 62
A customer configures HSRP between two data centers that are interconnected with OTV. The configuration succeeds, but traffic between two ESXi virtual hosts on the same site is routed suboptimally through the OTV overlay. Which two actions optimize the traffic? (Choose two.)
- A. Filter HSRP traffic by using a Layer 3 VACL on the ESXi vSwitch.
- B. Disable first-hop redundancy.
- C. Filter HSRP by using a Layer 2 MAC-list on the OTV edge devices.
- D. Filter HSRP traffic by using a Layer 3 VACL on the OTV edge devices.
- E. Filter HSRP by using a Layer 2 MAC-list on the ESXi vSwitch.
Answer: B,D
Explanation:
Section: Network
NEW QUESTION 63
Refer to the exhibit.
An engineer is configuring boot from iSCSI on a Cisco UCS B-Series Blade Server, but the LUN fails to mount. Which action resolves the issue?
- A. Configure an MTU size of 9000 on the appliance port.
- B. Set a connection timeout value of 250 in the iSCSI Adapter Policy.
- C. Statically configure the target information in the Boot Policy.
- D. Configure a QoS policy on the vNIC.
Answer: C
NEW QUESTION 64
......
The Cisco 300-615 test is what any IT professional planning to make big in the world of data center should take-up. With an unwavering focus on data center infrastructure and operations, this exam is here to generate an empowered and seasoned workforce that is capable to handle their responsibilities efficiently and help the company achieve its goals.
300-615 Dumps Full Questions with Free PDF Questions to Pass: https://www.testkingfree.com/Cisco/300-615-practice-exam-dumps.html
Free CCNP Data Center 300-615 Official Cert Guide PDF Download: https://drive.google.com/open?id=1sotQhOM8oh7nPX6lQs6XKH5RH6WNQsK2