Updated Jan-2022 Test Engine to Practice 500-920 Test Questions [Q21-Q40]

Share

Updated Jan-2022 Test Engine to Practice 500-920 Test Questions

500-920 Real Exam Questions Test Engine Dumps Training With 42 Questions


Cisco 500-920 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Troubleshoot storage area networks, including Fibre Channel, FCoE, zoning, NPV, and NPIV
Topic 2
  • Troubleshoot virtualization solutions
Topic 3
  • Troubleshoot FEX
Topic 4
  • Troubleshoot data center unified computing

 

NEW QUESTION 21
A Hard Drive (HDD) has been hot swapped in a UCS server blade, however, the UCS Manager GUI is not displaying updated metrics about the replacement drive. What action will be required to properly display updated metrics?

  • A. Use the CLI, since HDD metrics cannot be displayed with the UCS Manager GUI
  • B. Remove and re-insert the server blade HDD controller mezzanine card
  • C. Reboot the Fabric Interconnects
  • D. Reboot the server.

Answer: B

 

NEW QUESTION 22
You are experiencing intermittent connectivity issues on one specific Cisco UCS server Some applications work, while other do not transfer data You suspect jumbo frames limitations Which two places do you check the jumbo frame settings? (Choose two )

  • A. Check server's service profile and/or service profile template
  • B. Check server's QoS System Class
  • C. Check upstream switch ports frame size configuration
  • D. Check server's individual vNICs and/or vHBAs properties
  • E. Check the fibre channel port configuration for jumbo frame configuration

Answer: B,C

 

NEW QUESTION 23
After performing a UCS firmware upgrade, which two UCS components will require updated drivers? (Choose two )

  • A. RAID Controllers
  • B. Cisco Fabric Interconnects
  • C. Cisco UCS Manager
  • D. VIC Cards and Fiber Channel HBAs

Answer: B,D

 

NEW QUESTION 24
Which statement is true when using SPAN for Fibre Channel (FC) Traffic?

  • A. When defining FC uplink port as the SPAN destination, system will automatically stop using that port as an uplink port
  • B. For FC SPAN sessions we do not have to specifically enable the monitoring session
  • C. FC port on Cisco UCS 6238UP can be used as a SPAN source
  • D. Any port can be used as a SPAN destination port Even if it is defined as Eth uplink port it will be automatically converted to FC uplink port

Answer: C

 

NEW QUESTION 25
When configuring UCS SAN Connectivity to a 3rd Party FibreChannel Storage Array that is connecting directly to the UCS Fabric Interconnects, which option is Cisco recommended'?

  • A. Direct connectivity between UCS Fabric Interconnects and FibreChannel Storage Arrays is not supported
  • B. Connect the Storage Array to an Appliance Port and Enable NPV Mode on the UCS Fabric Interconnects
  • C. Connect the Storage Array to a RC Storage Port and Enable NPV Mode on the UCS Fabric Interconnects
  • D. Connect the Storage Array to an Appliance Port and Enable Switching Mode on the UCS Fabric Interconnects
  • E. Connect the Storage Array to a FC Storage Port and Enable Switching Mode on the UCS Fabric Interconnects

Answer: E

 

NEW QUESTION 26
What occurs that causes a Split Brain Issue with Fabric Interconnects?

  • A. Both cluster links fail
  • B. Manage configuration changes made with UCS Manager
  • C. The subordinate Fabric Interconnect detects heartbeat failure and declares itself primary
  • D. A quorum tie occurs that must be resolved by the SEEPROM

Answer: C

 

NEW QUESTION 27
Which statement best describes managing Cisco UCS servers using NX-OS CLI on the Fabric Interconnects?

  • A. The NX-OS CLI on the Fabric Interconnects allows you to view, but not change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
  • B. The NX-OS CLI on the Fabric Interconnects allows you to manage QoS parameters on the Fabric Interconnects and an upstream LAN switch
  • C. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
  • D. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the servers and Fabric Interconnects

Answer: C

 

NEW QUESTION 28
An overvoltage condition has occurred on a UCS server However the Cisco IMC System Event Log (SEL) file is full What is the resulting fault logging action?

  • A. The overvoltage condition event will not be recorded in the SEL.
  • B. The oldest entry in the SEL will be overwritten by the overvoltage condition event
  • C. The newest entry in the SEL will be overwritten by the overvoltage condition event.
  • D. The SEL is not used to record server related events, such as overvoltage conditions.

Answer: A

 

NEW QUESTION 29
Which two statements describes connecting the IO Modules in the UCS chassis to the Fabric interconnects? (Choose two )

  • A. Connect Fl-A to IOM A and IOM B in each chassis
  • B. Connect Fl-B to the IOM A of each chassis
  • C. Connect Fl-B to the IOM B of each chassis
  • D. Connect Fl-B to IOM A and IOM B in each chassis
  • E. Connect Fl-A to the IOM A of each chassis
  • F. Connect Fl-A to the IOM B of each chassis

Answer: C,E,F

 

NEW QUESTION 30
Which are two benefits of integrating Cisco UCS C-series servers with Cisco UCS Manager? (Choose two ) Cisco UCS Manager provides the ability to automatically update C-series firmware and device drivers from a single global interface.

  • A. Cisco UCS Manager can automatically power on and off servers to scale elastically according to application performance demands
  • B. Cisco UCS Manager is able to act as a common centralized management platform for both blade and rack servers in a single domain.
  • C. Cisco UCS Manager uses service profiles and resource pools to allow the deployment of multiple servers with a single common template
  • D. Cisco UCS Manager provides the ability to manage C-series in multiple physical domains from a single global interface

Answer: B

 

NEW QUESTION 31
Which two ports on a pair of Cisco Fabric Interconnects must be properly cabled for the pair to form a cluster? (Choose two )

  • A. L1 > L1
  • B. L2 > L2
  • C. L1 > L2
  • D. L2 > L1

Answer: A,B

 

NEW QUESTION 32
The UCS Chassis Discovery Policy has been set to four and a new chassis is connected with two links What is the resulting chassis recognition action?

  • A. The Chassis Discovery Policy will automatically reset to two links, since it always tracks the physical connections
  • B. The chassis will not be recognized
  • C. The chassis will be recognized and both links will be active
  • D. The chassis will be recognized but only one of the links will be active.

Answer: B

 

NEW QUESTION 33
What three options should be verified, when you are able to connect to Cisco UCS Manager, but unable to open a KVM session to a blade? (Choose three)

  • A. Verify TCP port 2068 is not blocked by an ACL or Firewall
  • B. Confirm the IP Address assigned to UCS Manager is the same as the KVM address
  • C. Verify the KVM IP Address is on the same subnet as the Fabric Interconnect management address
  • D. Confirm the IP Address assigned to the KVM is not a duplicate IP
  • E. Confirm the KVM IP Address is added to the route table in Cisco UCS Manager
  • F. Verify the KVM IP Address is on the same ip subnet as the virtual machines

Answer: A,D,E

 

NEW QUESTION 34
Which Cisco UCS internal component maintains the UCS XML database, manages the FSM stages and operations and instructs the Application Gateway to perform operations on physical and logical elements?

  • A. Cisco Finite State Machine
  • B. Cisco Application Gateways
  • C. Cisco Data Management Engine
  • D. Cisco UCS Manager

Answer: C

Explanation:
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/System-Monitoring/3-1/b_UCSM_GUI_System_Monitoring_Guide_3_1/b_UCSM_GUI_System_Monitoring_Guide_3_1_chapter_0100.html

 

NEW QUESTION 35
After installing a new UCS M4 server, which two Cisco Integrated Management Controller connectivity options do you have? (Choose two )

  • A. Out-of-Band Access
  • B. XML API Access
  • C. SNMP
  • D. In-band Access
  • E. Web Access

Answer: B,D

 

NEW QUESTION 36
You are in the process of upgrading your UCS M3 Server to a newer UCS M4 Server. You associate the Service Profile to the new UCS Server, but it fails to boot You suspect of a failed boot hard drive. You check your RAID1 Boot LUN in UCS Manager, but see no error messages What could be causing the issue?

  • A. A misconfiguration on the Service Profile Local Boot Policy
  • B. The newer Cisco UCS M4 Server is using disks of larger capacity than the previous UCS M3 Server
  • C. A misconfiguration on the Service Profile Local Disk Policy
  • D. The newer Cisco UCS M4 Server is using flash drives, not hard drives

Answer: D

 

NEW QUESTION 37
......

500-920 Actual Questions Answers PDF 100% Cover Real Exam Questions: https://www.testkingfree.com/Cisco/500-920-practice-exam-dumps.html