NEW QUESTION 74
NetCol5000-C temperature and humidity sensor dial setting is incorrect may result in ().

  • A. Temperature and humidity sensor cannot detect temperature and humidity
  • B. Water leakage at the bottom of the equipment
  • C. Equipment drainage capacity is significantly reduced
  • D. The return air temperature or fan speed fluctuates greatly

Answer: A

 

NEW QUESTION 75
The DX air cooled air conditioner has no limit on the installation distance.

  • A. TRUE
  • B. FALSE

Answer: B

 

NEW QUESTION 76
When the NeCol5000-A is under nitrogen pressure, the required nitrogen bottle must be equipped with a pressure reducing valve.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 77
NetEco does not support sending reports to customers by email.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 78
The reason for using the EPO status interface in the parallel step of the UPS5000-E is ().

  • A. Protect the battery from discharge
  • B. Prevent electric shock and protect personal safety
  • C. Cut off the output and set the parallel parameters
  • D. Power off the load to prevent damage to the load device

Answer: C

 

NEW QUESTION 79
The EPO status interface of the UPS5000-E can select a normally open or normally closed interface according to actual use.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 80
Whether the water distribution unit is equipped or not is based on installation scenarios

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 81
The gas fire extinguishing device is a fire extinguishing device composed of (). (Multiple choice)

  • A. Fire cylinder
  • B. Solenoid valve
  • C. Pressure switch
  • D. Sound and light alarm bell

Answer: A,B,C

 

NEW QUESTION 82
DuringNetCol5000-C commissioning, the opening of the water valve needs to be adjusted to minimum when you inject water and exhaust air.

  • A. TRUE
  • B. FALSE

Answer: B

 

NEW QUESTION 83
When two UPS5000-E share battery strings, the battery capacity of each UPS should be set to the total capacity of battery strings.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 84
ECC800 default management authority user name is admin, admin has all the rights to operate the web interface function.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 85
The following air conditioning systems need to be equipped with a cooling tower or dry cooler ().

  • A. Direct ventilation air conditioning system
  • B. CW air-cooled type
  • C. DX air-cooled type
  • D. DX water-cooled type

Answer: D

 

NEW QUESTION 86
Before battery installation, the open circuit of full capacity should be check.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 87
If a fire occurs in the FusionModule1000, the smoke detector and heat detector will send a fire alarm to the fire alarm control panel.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 88
In the battery model 6-GFM-150, 150 indicates the battery ().

  • A. Maximum capacity
  • B. Rated capacity
  • C. Minimum capacity
  • D. Actual capacity

Answer: B

 

NEW QUESTION 89
In ECO mode, the UPS works in ( ) when the input is stable.

  • A. Maintenance bypass
  • B. Battery
  • C. Normal
  • D. Bypass

Answer: D

 

NEW QUESTION 90
The user can modify the ECC800's IP address from the () menu of the ECC800 Web interface.

  • A. Monitoring module IP
  • B. Time setting
  • C. Emblem module settings
  • D. Video IP settings

Answer: A

 

NEW QUESTION 91
Check that the load switch is in the "OFF" position before powering up the URS5000.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 92
When four UPS2000-G-20K parallel setting is "3+1", the capacity of the system is ( ) KVA.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

 

NEW QUESTION 93
Which component does not support wireless networking?

  • A. XXX
  • B. AC Actuator
  • C. Access actuator
  • D. ETH converter

Answer: D

 

NEW QUESTION 94
The battery capacity should be set to ( ) when three 9Ah battery groups are parallel connected to UPS2000-G-15kVA

  • A. 18Ah
  • B. 27Ah
  • C. 32Ah
  • D. 9Ah

Answer: A

 

NEW QUESTION 95
When doing maintenance of UPS5000-E, make sure loads continue to powered, we should first perform EPO and then turn the maintenance bypass switch.

  • A. TRUE
  • B. FALSE

Answer: B

 

NEW QUESTION 96
If the ECC800 is configured with a SIM card, the SIM card should be installed in ().

  • A. ECC800 main control module left slot
  • B. USB interface
  • C. ECC800 power module slot
  • D. Below the ECC800 antenna port

Answer: A

 

NEW QUESTION 97
At present, the industry PUE value can be optimally achieved ( ).

  • A. 0
  • B. 0.5
  • C. -0.5
  • D. 1.06

Answer: D

 

NEW QUESTION 98
Huawei Fusion Module2000 monitoring system supports users on which to monitor the status of micro-modules? (Multiple choice)

  • A. Mobile APP
  • B. NetEco web interface
  • C. ECC 800Web interface
  • D. PAD APP

Answer: A,B,C,D

 

NEW QUESTION 99
......